+86-21-5432 2103

PV Module Aging Test Location: 首页 > Product Solutions > PV Module Aging Test > PID Test System (Single Control Scheme)

PID Test System (Single Control Scheme)

Product description Specifications Download

Meet the PID test requirement specified in the IEC62804 standard. The system could also be used at actual outdoor conditions.

l  The frame end of the module is grounded, which not only simulates the actual situation, but also prevents the potential danger caused by the high pressure of the frame during the test process.

l  For each module, use the 4-wire test method, that is 2 high-voltage cables, and 2 ground cables. The high-voltage cables are connected to the inside of the module through the terminal box. The ground wire is connected to the frame or connected to other effective positions.

l  Multiple currents are displayed at the same time, while alarm parameters are set separately, with single-circuit on/off control.

l  Multi-channel voltage settings are programmed separately and the voltage can be set as required.

l  forward and reverse voltage could be set by program.

l  Conversion of positive power supply and negative power supply, which is simulation of positive ground or negative ground.

l  Can set test time, and stop automatically.

l  The screen shows the test situation, and record the test data.

l  Test channels can be customized according to customer needs.

l  Can test and record environmental parameters and temperature parameters.



Item

Parameters

PID supply

Size

650mm*650mm*1600mm

Weight

30kg

Voltage range

-1500V0V/ 0+1500V

Alarm setting range

11000   uA /-1000 uA1

Insulation resistance

1000MΩ

Channel

8

Chamber

Internal Dimension

1800*1500*2400mm(W*D*H)

Temperature   range

RT+10+110℃

Temperature   control stability

±0.5℃

Temperature   uniformity

±2.0℃

Heating rate

Meet the heating rate of 5°C/min.

Humidity control range

7095%RH

Humidity control stability

±2.0%RH

Humidity uniformity

±3.0%RH